What we do

IAT carries out non-destructive testing and diagnostics in the civil and industrial fields on in-service structures and plants, with specialised technicians, for scheduled, periodic and extraordinary verifications.

Results do not stay a test report: they are interpreted in terms of asset integrity to support decisions on maintenance, repair, replacement or life extension.

Services

Full list of activities, organised by group.

Non-destructive testing on materials and welds
  • Visual testing (VT)
  • Radiographic testing (RT)
  • Ultrasonic testing (UT) and Phased Array (PAUT)
  • Ultrasonic thickness measurement
  • Penetrant testing (PT)
  • Magnetic particle testing (MT)
  • Eddy current testing (ET)
  • Infrared thermography
  • Cleanliness and contamination control
  • Acoustic vibration analysis
Structural diagnostics
  • Rebound hammer and magnetometric (cover meter) surveys
  • Sonic and ultrasonic surveys
  • Flat-jack tests
  • Pull-Out and Pull-Off tests
  • Crack-pattern monitoring
  • Load tests on slabs, foundation piles, plates, bridges and viaducts
  • Endoscopy
  • Ground-penetrating radar
  • Topographic surveys
Periodic and conformity verifications
  • Periodic verification of tanks, road tankers and pressure vessels
  • Verification of electrical and earthing installations
  • Verification of electromedical equipment
  • Reliability diagnosis of in-service components
  • Conformity verification of plants, parts and components
  • Support for CIVA / INAIL platform obligations, where applicable

The problems we address

  • 01

    “I need to decide whether a slab, bridge or structure can take a new load.”

  • 02

    “I have welds, piping or vessels in service and want to know residual thickness and defects before they become a failure.”

  • 03

    “I want to plan maintenance on condition rather than fixed intervals.”

  • 04

    “I have mandatory periodic verifications on equipment and installations and want a single point of contact.”

How IAT works

  • The test method is chosen according to material, expected defect and the decision to be taken.
  • Test reports readable by decision-makers: result, criticality, recommendation.
  • Integration with IAT engineering to move from data to action.

Regulatory framework

  • UNI EN ISO 9712 (NDT personnel qualification) and applicable product standards
  • Ministerial Decree 11 April 2011 — periodic verification of work equipment
  • Presidential Decree 462/2001 — earthing system verification
  • Ministerial Decree 17/01/2018 — Technical Standards for Construction (tests on existing structures)

References are indicative. Each engagement is framed on the regulations in force at the time of appointment.